SINOCARE PCH-50 portable glycated hemoglobin ananlyzer

21 Agustus 2025 PT. Arvindo Karya Utama memulai pemasangan Alat PCH-50 portable glycated hemoglobin ananlyzer di RS. Baiturrahim JAMBI.

SINOCARE

PCH-50 portable glycated hemoglobin ananlyzer

* Easy to carry

* Easy to operate

* Communicate with LIS

* Quick test

# Clinical Significance of HBA1C :

the gold standard for assessing long-term diabetes screening, HBA1C >7% as an important judgment criterion for initiating clinical treatment or the need to adjust the treatment plan for type 2 diabetes

Type 2 diabetes : in the early stage of treatment, it is recommended to test once every 3 months, and after the blood glucose control reaches the standard, it can be checked once every 6 months.

Type 1 diabetes : on the basic of avoiding hypoglycemia, HBA1C < 7,5% in children and adolescents ; HBA1C < 7.0% in adulthood should be achieved.

#Application Scenarios

Application scenarios : primary institution (low amount of daily test and cost – effectiveness)

PCH-50 Portable glycated hemoglobin analyzer

  • ACCURACY

Sinocare portable hemoglobin analyzer (PCH-50) was compared with fully automatic hemoglobin analyzer (HPLC method) produced by an internasional famous brand.

The results showed that accuracy of sinocare PCH-50 was highly consistent with the HPLC method and the precision of the test results was excellent. (300 clinical samples, including 200 cases of venous blood and 100 cased of fingertip blood).

  •  Certification

 


PCH-50 Portable Glycated Hemoglobin Analyzer

Specifications

Sinocare PCH-50 Analyzer

Language : Simplifed chinese, English

Screen : Dot matrix screen, 240 x 160 pixels

Additional Function : USB, Bluetooth 4.2

Power Input : 7.5 V DC 1A

Dimension : 191mm x 155mm x 60mm (Length x Width x Height)

Net Weight Of Instrument : About 450g

Data storage capacity : 500 test values, 20 quality control values

Operation environment : Ambient temperature: 10’C – 35’C : Humidity: < 85%RH

Storage Condition : -20-55’C.

Sinocare PCH-50 Test Kit

Principal : Boric acid affinity liquid chromatography

Sample type : Fresh capilary whole blood, venus wholle blood

Measurement range : 4%-15% HbA1c

Sample volume : 5 u L

Test time : < 3.5min

Storage Condition : 2-8 ‘C

Accuracy : HbA1c samples (4%-6%), the absolute deviation <+0.6% HbA1c : HbA1c Samples (6.1%-15.0%), Relative deviation <+10.0%

Precision : CV < 8.0%

Expriation date : 12 Months from manufacture

Packing Spesification : 30 pcs/box, 50 pcs/box, individual packed test trip.